HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
6005 8809
Please wait. Retry Add Pair
(Paircreate)/Resume Pair
(Pairresync) operation in a
few minutes.
Add/resume pair operation
failed. The specified volume
or another volume in the
same group being changed
to simplex/suspend status
in RCU. A few minutes
later, renew and check the
Continuous Access screen
and if specified volume is in
a permissible status retry the
operation.
i
4
6005 8810
TrueCopy Asynchronous for
Mainframe function is not
installed in the specified
RCU.
Install TrueCopy
Asynchronous for
Mainframe in the RCU
and retry the operation.
i
4
6005 8811
This vers
ion does not support
multiple
CT Groups in the
RCU.
This microcode version does
not suppor t multiple CT
groups in the RCU. Verify
the status and retry.
i
4
6005 8812
This version does not
support the coexistence
of Continuous Access
Asynchronous pairs and
Synchronous pairs in the
same DKC subsystem(s).
The add pair operation
failed. This version does
not support the intermix
of Continuous Access
Asynchronous pairs and
Synchronous pairs in the
same DKC. Refresh the
screen and confirm the
Copy Mode in the MCU
and RCU.
i
4
6005 8813
The specified M-VOL
is a ShadowImage for
Mainframe, Business Copy,
or FlashCopy Mirror volume.
This version does not support
it.
This microcode version
does not support Business
Copy/FlashCopy Mirror,
and the specified M-VOL is
aBusinessCopy/FlashCopy
Mirror volume. V erify the
status of the M-VOL and
retry .
i
4
6005
8814
The specified R-VOL is
a ShadowImage for
Mainframe, Business Copy,
or FlashCopy Mirror volume.
This version does not support
it.
T
his microcode version
d
oes not support Business
C
opy/FlashCopy Mirror,
and the specified R-VOL is
aBusinessCopy/FlashCopy
Mirror volume. V erify the
status of the R-VOL and retry.
i
4
6005 8815
Continuous Access
Asynchronous function is
not installed in the specified
RCU.
Install the Continuous Access
Asynchronous function in
the RCU, and then retry the
operation.
i
4
6005 8816
Add Pair (Paircr eate)
operation failed because
combining TrueCopy
Asynchronous for
Mainframe pairs and
Continuous Access
Asynchronous pairs is
not allowed in one CT
Group.
The operation failed
because TrueCopy
Asynchronous for
Mainframe pairs cannot
be mixed with Continuous
Access Asynchronous pairs.
Verify the status, and then
retry the operation.
i
4
200