HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6005
87 64
The spec ified R-VOL is
not usable, or th e device
emulation type of the
R-VOL is not supported by
Continuous Access via serial
interface.
Please confirm the
status of the specified
R-VOL. P lease see the
OPENPLATFORM SECTION
in the maintenance manual
to confirm whether the
device emulation type of
the R-VOL is supported by
Continuous Access via serial
interface.
W4
6005 8765
Data Migration is not
supported under the M-VOL
Device emulation type.
Thedeviceemulationtype
of the specified M-VOL
does not support data
migration. Please call
technical support.
i
4
6005 8766
Continuo
us Access is not
supporte
dundertheR-VOL
Device e
mulation type.
The devic
e emulation type of
the R-VOL
does not support
Continuo
us Access. Please
call tec
hnical suppor t.
i
4
6005 8767
Data Migration is not
supported u nder the R-VOL
Device emulation type.
The R-VOL device emulation
type does not support data
migration. Please call
technical support.
i
4
6005 8768
The RCU is still in
another Continuous Access
condition.
The RCU containing the
R-VOL is being used as the
RCU for Continuous Access.
Verify the status of the RCU,
if necessary delete the RCU,
and then retry the operation.
E
4
6005 8769
The RCU is still in
another Continuous Access
condition.
The R
CU containing the
R-V
OL is being used as the
RCU for Continuous Access.
Verify the status of the RCU.
E
4
6005 87 70
TheCacheontheMCUis
automatically recovering.
Please wait a few minutes
then retry again.
Select [OK] to acknowledge
the message, and then
retry the operation after the
cache has been recovered.
i
4
6005 87 71
R-VOL option change
operation failed. Only
M-VOL o ption was modified
because RCU side did
not s upport a fence level
displaying function.
The R-VOL option change
operation failed (only
the M-VOL option was
modified), because t he RCU
side does not support the
display fence level function.
i
4
6005 87 72
Change pair operation
failed due to communication
errorortheR-VOLstatusis
invalid.
The pair option change
operation failed, either
because a communication
erroroccurredorbecause
the R-VOL status is not valid.
Please verify the status. Also
view the License K ey window
at the RCU side and check
the licensed capacity for
Volume Retention Manager.
If th e licensed capacity for
Volume Retention Manager
is insufficient, purchase a
E
4
Remote Web Console error codes
195