HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
6005 8751
Continuous Access is not
supported under the RCU
Controller emulation type, or
the CT Group is not usable.
Add Pair operation failed.
1. Confirm the controller
emulation type, and
see the manual.
2. Confirm the CT Group
number in the MCU.
i
4
6005 8752
Data Migration is not
supported under the RCU
Controller type.
The RCU controller
emulation type does not
support data migration.
Please call technical support.
i
4
6005 8753
An internal error occurred. Please call technical support.
E
4
6005 8754
Invalid MCU serial number
or MCU SSID.
Check the serial number or
SSID of MCU, and then retry
with correct parameter.
E
4
6005 8755
The serial number , SSID or
CU number of the RCU is
invalid.
1. Check the serial
number, SS ID or CU
number of the RCU, and
retry the operation with
correct parameters.
2. Check the connection
LCP ports of the RCU.
Connect the path
correctly, and retry the
operation.
E
4
6005 875 6
MCU disk array cache is
not active.
Check
the storage system
cache status of the MCU
from the host. If it is off, set
it on and retry. If it cannot
be set on, call technical
support.
i
4
6005 8757
OnesideofMCUCacheis
blocked.
Please call technical support.
W4
6005 875 8
Unexpected error on MCU. Please call technical support.
W4
6005 8759
RCU Subsystem Cache
status is not acti ve.
Pl
ease call technical support.
i
4
6005 8760
M-VOL and R-VOL Track
Formats do not match.
Checkthetrackformatsof
the specified M-VOL and
R-VOL.
i
4
6005 8761
The emulation types or the
capacities of M-VOL a nd
R-VOL do not match.
Verify that the emula tion
types and the capacities of
the specified M-VOL and
R-VOL match.
i
4
6005 87 62
R-VOL Device Cache status
is not active.
Check the device cache
status of R-VOL from host. If
itisoff,setitonandretry.
If it cannot be set on, call
technical suppor t.
i
4
6005 8763
R-VOL DFW status is not
active.
Check the DFW status of
the R-VOL from the host. If
itisoff,setitonandretry.
If it cannot be set on, call
technical suppor t.
i
4
194