HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)

Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6005
8724
Specied number of paths
is less than the minimum
specied on RCU Option
screen.
The specied number of
pathsislessthanthe
minimum number of paths
specied on the RCU Option
window.
i
4
6005 8725
Current microprogram
version does not suppor t the
specied operation.
The version of the microcode
on the storage system does
not support the specied
function or operation.
Please call technical support.
i
4
6005 872 7
The number o
f minimum
paths excee
ds the number
of normal pa
ths.
Please add the normal
path(s), and then set the
minimum number of paths.
i
4
6005 8726
Multi platform feature
already installed in MCU.
The multi platform feature
has already been installed
intheMCU.Pleaseverify
the conguration of the
MCU.
i
4
6005 872 7
The number of minimum
pathsexceedsthenumber
of normal paths.
Please add the normal
path(s), and then set the
minimum number of paths.
i
4
6005 8728
The numb
er of minimum
paths e
xceeds the number
of norm
al paths.
Please t
ake either of the
followi
ng actions:
1. Add norm
al paths, and
then de
lete the paths.
2. Decrea
se the number
of mini
mum paths, and
then d
elete the paths.
i
4
6005 8729
An internal error occurred. Please call technical support.
E
4
6005 8730
Invalid Logical Addresses
are specied.
1. If you are adding RCUs,
specify the same logical
address.
2. If you are editing paths,
specify the same logical
address as the existing
paths. (See the Edit
Path Screen.)
i
4
6005 8731
The existing logical
addresses are not equal.
The logical addresses of
all existing paths are not
the same. Delete the RCU,
and then re-add it, using
the same logical address as
other existing paths.
i
4
6005 873 2
Too many SSIDs (Only Four
SSIDs are allowed).
The maximum number
of SSIDs (four) has been
entered. Verify that the
SSIDs are valid, delete one
or more, and then retry the
operation.
E
4
6005 8733
The Fibre-Continuous Access
function is not installed in
the specied MCU.
Please install the program
product key in the MCU.
i
4
Remote Web Console error codes