HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)

Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
6005 8001
A time-out error occurred.
Retry the operation. If
yougetthesamemessage
again, reboot the computer.
If necessary, Please call
technical suppor t.
E
4
6005 8100
A time-out error occurred.
Retry the operation. If
yougetthesamemessage
again, reboot the computer.
If necessary, Please call
technical suppor t.
E
4
6005 8104
Ittakestimeforthechange
processing
of pair status.
Please wait for a while,
and then refresh the screen
and conrm the pair
status has been changed
properly
. If the pair status
is not ch
anged, check the
MCU/RCU conguration
and the
condition of the
paths b
etween the CUs.
It takes time for the change
processing
of pair status.
Please wait for a while,
and then refresh the screen
and c onrm the pair
status has been changed
properly
. If the pair status
is not ch
anged, check the
MCU/RCU conguration
and the
condition of the
paths b
etween the CUs.
i
4
6005 8700
Please retry operation. Retry the operation.
i
4
6005 8701
Logical Path between the
MCU and the RCU is not
active.
A logical path does not exist
between the MCU and the
RCU. Check the p ath status
on RCU Status screen, and
reestablish the paths with
Edit Path.
i
4
600
5
870
2
The pair status of the M-VOL
is not valid.
Thepairstatusisnota
permissible type for this
operation. Renew and
check the screen. If the
M-VOL status permits
the operation, retry the
operation.
i
4
6005 8703
The specied number
ofPathsislessthanthe
Minimum number of Paths
on RCU Option screen.
The number of paths is less
than the minimum number
specied on the RCU Op tion
screen. Check the number
of paths, establish the
minimum number of paths,
and retry the operation.
i
4
6005
8704
The specied number of
pathsislessthanthe
minimum number of paths
on the RCU option screen
due to a communication
error between the MCU
and the RCU, or the device
emulation type of the
R-VOL is not supported by
Continuous Access via serial
interface.
Please check the paths
status on the RCU Status
screen, and reestablish
the paths on the Edit Path
screen. Please see the
OPENPLATFORM SECTION
in the maintenance manual
to conrm whether the
device emulation type of
the R-VOL is supported by
Continuous Access via serial
interface.
W4
188
HP StorageWorks XP Remote Web Console for Storage System M essages and Error Codes