HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)

Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
1005 1004
Multiple volumes are
specied to a single port,
group or LUN combination.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
1005 1005
The following volumes
cannot be specied
when you change path
congurations:
Volumes that do not exist
Volumes other than top
LUs in expanded LUs
Volumes reserved by
Auto LUN
Volumes to which the Just
in Time Storage function
is applied
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
1005 1007
Failed to remove the path.
The specied path is the last
path of the volumes used for
Continuous Access, Business
Copy, Cross-system Copy,
Auto LUN, or XP Snapshot.
Check t
he setting.
E
6
1005 1009
The emulation type of the
volumes combined into a
LUSE volume is not for open
systems.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
1005 1010
An error occurred during
SVP processing. If this
problem persists, please call
technical suppor t.
If this problem persists, call
technical suppor t.
E
2
1005 1011
An error occurred. If this
problem persists, please call
technical suppor t.
The volume which links as
an expanded LU extend
ov er CU#. The error does
not occur normally because
it is guarded in the screen.
Contact the program maker.
E
2
1005 1012
LU path is set to a volume
which links as an expanded
LU.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
1005 1013
The emulation types of the
volumes combined into a
LUSE volume are not the
same.
The emulation type of a
volume which links as an
expanded LU is not the
same. The error does not
occur normally because it
is guarded in the screen.
Contact the program maker.
E
2
108
HP StorageWorks XP Remote Web Console for Storage System M essages and Error Codes