HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
0605
58254
The P-VOL and the S-VOL of
the Cross-system Copy pair
are both external volumes
whose IO Suppression
mode is set to Disable.
Create a Cross-system Copy
pair using an external
volume and a n internal
volume.
E5
0605 5825 5
An external volume whose
IO Suppression mode is
set to Disable and an
external volume whose IO
Suppression mode is set to
Enable are specified as the
P-VOL and the S-VOL of the
Cross-system Copy pair.
Create a Cross-system Copy
pair using an external
volume and a n internal
volume.
E5
0605 58256
An external volume whose
IO Suppression mode
is set to Enable and an
external volume whose IO
Suppression mode is set to
Disable are specified as the
P-VOL and the S-VOL of the
Cross-system Copy pair.
Create a C
ross-system Copy
pair usi
ng an external
volume a
nd an internal
volume.
E5
0605 5825 7
The P-VOL and the S-VOL of
the Cross-system Copy pair
are both external volumes
whose IO Suppression
mode is set to Enable.
Create a Cross-system Copy
pair using an external
volume and a n internal
volume.
E5
0605 58258
All the paths to the external
volume are blocked.
Restore the blocked path
status, and then retry the
operation.
E5
0605 58263
No paths will be available,
if you change the setting of
paths.
Make
the setting of th e
path
s to keep at least one
pat
h available, and then
ret
ry the operation.
E5
0605 58299
The command has been
rejected, because the
specified P-VOL is set for
use in Continuous Access
Journal operations.
You cannot execute the
specified operation.
Release the Continuous
Access Journal setting for
the operation.
E5
0605 58300
The command has been
rejected, because the
specified S-VOL is set for
use in Continuous Access
Journal operations.
You cannot execute the
specified operation.
Release the Continuous
Access Journal setting for
the operation.
E5
0605 58301
The command has been
rejected, because the
specified volume is set for
use in Continuous Access
Journal operations.
You cannot execute the
specified operation.
Release the Continuous
Access Journal setting for
the operation.
E5
0605 58330
After Disconnect Subsystem
or Disconnect Volume is
executed, neither Disconnect
Paths nor Check paths can
be executed.
Please execute Check Path
&RestoreVolumeinsteadof
Disconnect paths or Check
paths.
E5
0605 58331
The path requested by
Disconnect paths or Check
paths was not found.
If this problem persists, call
technical suppor t.
E5
100
HP StorageWorks XP Remote Web Console for Storage System M essages and Error Codes