HP StorageWorks Performance Control XP user guide (T1605-96007, October 2007)
Performance Control XP user guide 71
NOTE: Ensure that mm is 00, 15, 30, or 45. If you do not specify mm in this way, the value on the left of
the colon (:) is rounded down to one of the four values. Also, the value on the right of the colon is rounded
up to one of the four values. For example, if you specify 200401010013:200401010048, the specified
value is regarded as 200401010015:200401010100.
Example
The following examples assume:
• Starting time for collecting monitoring data is Jan.1, 2004, 00:00
• Ending time for collecting monitoring data is Jan. 2, 2004, 00:00
The Export Tool saves monitoring data within the range of Jan.1, 9:30-17:30.
The Export Tool saves monitoring data within the range of Jan.1, 9:30 to Jan. 2, 00:00.
The Export Tool saves monitoring data within the range of Jan.1, 0:00-17:30.
The Export Tool saves monitoring data within the range of Jan.1, 0:15 to Jan. 2, 00:00.
The Export Tool saves monitoring data within the range of Jan.1, 23:45 to Jan. 2, 00:00.
The Export Tool saves monitoring data within the range of Jan.1, 0:00-00:15.
The Export Tool saves monitoring data within the range of Jan.1, 0:00-23:45.
The Export Tool saves monitoring data within the range of Jan.1, 1:15-22:45.
The Export Tool saves monitoring data within the range of Jan.1, 10:30-15:30.
The Export Tool saves monitoring data within the range of Jan.1, 7:30-18:30.
The Export Tool saves monitoring data within the range of Jan.1, 7:30 to Jan. 2, 00:00.
longrange 200401010930:200401011730
longrange 200401010930:
longrange :200401011730
longrange +000015:
longrange -000015:
longrange :+000015
longrange :-000015
longrange +000115:-000115
longrange 200401010900+000130:200401011700-000130
longrange 200401010900-000130:200401011700+000130
longrange 200401010900-000130: