HP StorageWorks Performance Control XP user guide (T1605-96007, October 2007)

70 Performance Control Export Tool
The longrange subcommand is valid for monitoring data in long range. Monitoring data in long range is
the contents displayed in the Physical tab of the Auto LUN XP pane with selecting longrange as the
storing period. Monitoring items whose data can be stored in long range are limited. Table 25 shows
monitoring items to which the longrange subcommand can be applied, and also shows operands to
export those monitoring items.
If you run the Export Tool without specifying the longrange subcommand, data stored in the whole
monitoring term is exported.
The login subcommand must execute before the longrange subcommand executes.
Operands
The value on the left of the colon (:) specifies the starting time period. The value on the right of the colon
specifies the ending time period. Specify the term within Long Range From XXX To XXX which is
output by the show subcommand.
If no value is specified on the left of the colon, the starting time for collecting monitoring data is assumed.
If no value is specified on the right of the colon, the ending time for collecting monitoring data is assumed.
The starting and ending times for collecting monitoring data appear in the Monitoring Term area in the
Auto LUN XP pane (see Figure 28).
Figure 28 Starting and ending time for collecting monitoring data
yyyyMMddhhmm
yyyyMMdd indicates the year, month, and day. hhmm indicates the hour and minute.
If yyyyMMddhhmm is omitted on the left of the colon, the starting time for collecting monitoring data is
assumed. If yyyyMMddhhmm is omitted on the right of the colon, the ending time for collecting
monitoring data is assumed.
+ddhhmm
Adds time (ddhhmm) to yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,
200401120000+010130 indicates Jan.13, 2004, 01:30.
Adds time to the starting time for collecting monitoring data if yyyyMMddhhmm is omitted.
-ddhhmm
Subtracts time (ddhhmm) from yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,
200401120000-010130 indicates Jan.10, 2004, 22:30.
Subtracts time from the ending time for collecting monitoring data if yyyyMMddhhmm is omitted.
Table 25 Monitoring items to which the longrange subcommand can be applied
Monitoring data Operands of the group subcommand
Usage statistics about parity groups PhyPG Long
Usage statistics about logical volumes PhyLDEV Long
Usage statistics about channel processors, disk processors, and data
recovery and reconstruction processors
PhyProc Long
Usage statistics about access paths and write pending rate PhyCSW Long