HP StorageWorks LUN Configuration and Security Manager XP User Guide for the XP1024/XP128 (T1614-96005, March 2006)

LUN Configuration and Security Manager XP user guide for the XP1024/XP128 13
1LUN Manager for the XP1024/XP128
You can connect XP arrays to open system and mainframe hosts using iSCSI (Internet Small Computer
System Interface) and Fibre Channel. Use LUN Manager to configure host groups, logical units (LUs), and
Fibre Channel ports.
LU configuration overview
One of the important tasks in logical unit (LU) configuration is to define I/O paths from hosts to LUs. After
the paths are defined, the hosts can send commands and data to the LUs and can receive data from them.
LUN Manager can also configure security policies to protect LUs from unauthorized access.
Fibre Channel environment
In a Fibre Channel environment, you must configure the Fibre Channel ports on the disk array. With LUN
Manager, you can set addresses and speed, and specify topology for Fibre Channel ports.
iSCSI environment
In an iSCSI environment, the XP disk array provides mutual user authentication between hosts and ports
by using Challenge Handshake Authentication Protocol (CHAP).
Supported emulation types
LUN Manager supports the following device emulation types:
OPEN-3, OPEN-9, OPEN-8 (XP1024/XP128 only), OPEN-E, OPEN-L, and OPEN-V for open systems
3390-3A/B/C and 3380-KA/B/C for mainframe systems
LU paths
After hosts and the disk array are physically connected by cables, switches, and so on, use LUN Manager
to establish paths between the hosts and LUs. These paths are called LU paths and they determine which
host can access which LU.
Up to 256 LU paths can be defined for a host group in a Fibre Channel or iSCSI environment
Up to 512 LU paths can be defined for a Fibre Channel port for the XP1024/XP128 arrays
Up to 128 host groups can be defined for a Fibre Channel port for the XP1024/XP128 arrays
In an iSCSI environment, you can define:
Up to 16 initiators per port
Up to 16 host groups per port
Up to 16 initiators per host group
NOTE: In an iSCSI environment, the number of initiators per host group multiplied by the number
of host groups must be less than or equal to 16.
Up to 65,536 host groups can be defined for one disk array (256 x 256)
Up to 255 hosts can be included in all the host groups for one Fibre Channel port
Up to 16 hosts can be included in all the host groups for one iSCSI port
Configuring LU paths in a Fibre Channel environment
Before defining LU paths, you must classify server hosts by host storage domains. For example, if Linux
and Windows hosts are connected to the disk array, you must create a separate host storage domain for
each host type. When this is done, register the host bus adapters for each host type in the appropriate
host storage domain.