HP StorageWorks External Storage XP user guide (December 2005)

80 External Storage XP for the XP10000/XP12000
NOTE: You can either specify or omit any other parameters.
Lightning 9900V Series subsystem
When connecting a Lightning 9900V Series subsystem as the external disk array, you must set the port to
the host group for the Windows host (host mode 0C: Windows, host mode 2C: Windows Extension).
Also, the port attribute must be the target or RCU target port.
Table 11 System parameter settings (TagmaStore AMS and TagmaStore WMS)
Pane name Parameters Parameter setting
Boot Options Start Attribute
Single Mode Specify this parameter when the TagmaStore
AMS or TagmaStore WMS subsystem is in
the one-controller configuration.
Dual Active Mode Specify this parameter when the TagmaStore
AMS or TagmaStore WMS subsystem is in
the two-controller configuration.
NOTE: Be sure to specify that Data Share
Mode will be used.
Delay Planned Shutdown You can either specify this parameter or omit
specifying this parameter.
Drive blocking mode You can either specify this parameter or omit
specifying this parameter.
Vendor ID Keep this parameter as HITACHI (default),
and do not change.
Product ID Keep this parameter as DF600 (default), and
do not change.
ROM Microprogram Version You can either specify this parameter or omit
specifying this parameter.
RAM Microprogram Version You can either specify this parameter or omit
specifying this parameter.
System Parameter Option You can either specify this parameter or omit
specifying this parameter.
Operation if the processor failure occurs Set this parameter to Reset of occurred.
WEB Title You can either specify this parameter or omit
specifying this parameter.
Write and verify mode Set this parameter to ON.
Port Options Port Option You can either specify this parameter or omit
specifying this parameter.
Host Connection
Mode
Host Connection Mode 1 Set this parameter to Standard Mode.
Host Connection Mode 2 Do not specify any parameters.
NOTE: Do not specify HISUP OFF mode,
either.