HP StorageWorks External Storage XP user guide (December 2005)
External Storage XP user guide 79
NOTE: When using the Thunder 9500V Series subsystem as an external disk array, the following versions
are recommended. If you use a 9500V Series subsystem whose version is earlier than the following
versions, the SATA drive’s information might not be displayed correctly.
• For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later
• For Thunder 9580V, Thunder 9585V: version 1658 or later
TagmaStore AMS and TagmaStore WMS subsystems
Table 11 explains whether to specify system parameters when making settings on ports on the TagmaStore
AMS and TagmaStore WMS subsystems.
Data Striping Operation if the processor failure occurs Set this parameter to Reset of occurred.
Inquiry Setting Command Queuing Mode Set this parameter to ON.
Vendor ID Keep this parameter as HITACHI (default),
and do not change.
Product ID Keep this parameter as DF600 (default),
and do not change.
ROM Microprogram Version You can either specify this parameter or
omit specifying this parameter.
RAM Microprogram Version You can either specify this parameter or
omit specifying this parameter.
WEB Title You can either specify this parameter or
omit specifying this parameter.
Port Type Reset/LIP Mode
• Reset/LIP Mode (Signal) You can either specify this parameter or
omit specifying this parameter.
• Reset/LIP Mode (Process) You can either specify this parameter or
omit specifying this parameter.
• LIP Reset Mode You can either specify this parameter or
omit specifying this parameter.
Controller Option RS232C Error Information Outflow Mode You can either specify this parameter or
omit specifying this parameter.
Write and verify mode Set this parameter to ON.
Host Connection Mode Host Connection Mode 1 Set this parameter to Standard Mode.
Host Connection Mode 2 Specify HISUP Mode.
NOTE: Do not specify any other
parameters.
Table 10 System parameter settings (Thunder 9500V Series subsystem) (continued)
Pane name Parameter Parameter setting