HP StorageWorks External Storage XP user guide (December 2005)

58 External Storage XP for the XP10000/XP12000
Product
The external disk array product name
Serial
The external disk array serial number
Group
The external LU group and reference number
Characteristic
Identification number of external LU.
Device
The external LU device type
Capacity
Capacity of external LU
Alternate Path List
Status of alternate paths. The Alternate Path list consists of two tables. The Configured Paths table
displays previously defined paths. The Available Paths table displays available paths. The Alternate
Path list displays the following information:
Port: The local disk array port number
WWN: Identification number of the external disk array port.
LUN: The external LU number.
Priority: Priority of paths connecting to external LU. A 1 indicates the path with the highest priority.
Status: Status of path to external LU. For information on reacting to status displayed, see
Troubleshooting External Storage XP” on page 74. Possible values:
Normal: Path status is normal
Unknown: Path status is unknown.
Blockade: I/O traffic is blocked.
External device setting changed: Something about the external disk array has changed. For
example, a path definition was deleted or the external disk array was replaced.
LDEV size reduced: The volume capacity of the external disk array has changed (volume
capacity was reduced)
Not ready: The external disk array replied NOTREADY.
Illegal request: The external disk array replied ILLEGALREQUEST
Command aborted: External disk array replied ABORTEDCOMMAND
Busy: The external disk array status is BUSY
LDEV reserved: The external disk array status is Reserve
Response error: The status of the external disk array is blocked because of an abnormal reply
(Response)
Initiator port: The port attribute of the external disk array changed to initiator
RCU target port: The port attribute of the external disk array changed to RCU target
Unknown port: The port attribute of external disk array is unknown
Cannot detect port: The path was removed or the external disk array port cannot be found
Internal error: A program error occurred, or there is a logical contradiction
Timeout: Processing was retried because of an abnormal reply, but a timeout has occurred
Checking: External Storage XP is checking defined configuration information of paths
Disconnect: The connection to the external disk array or LU was stopped using the Disconnect
Subsystem or Disconnect Volume command
Unavailable: The external disk array replied Unavailable. The external disk array requests to
change the connected port. After the status becomes Unavailable, the primary path changes to
the alternate path that is in the Standby status. When the primary path changes, the status of the
path becomes Normal.