HP StorageWorks Continuous Access XP user guide for the XP10000/XP12000 (December 2005)

Continuous Access XP user guide for the XP10000/XP12000 73
NOTE: After being set, options can be modified and canceled (see ”Modifying parameters and
deleting settings” on page 75).
7. Click Apply on the Continuous Access XP main pane to apply the settings to the disk array. The MCU
automatically begins using the new logical path for Continuous Access XP activities.
Deleting paths from the connected MCU to an existing RCU:
Before deleting a path to an RCU, ensure that remaining number of paths is equal to or greater than
minimum number of paths setting (selected on the RCU Option pane). The delete path operation fails if
number of remaining paths is less than minimum number of paths.
1. Open the RCU Option pane, and check the minimum number of paths setting. If the remaining number
of paths is less than this value, the delete path operation will fail. If needed, change the minimum
number of paths so you can delete the path.
2. From the CU Number/Port tree on the RCU Operation pane, ensure that the correct CU image is
selected.
3. From the MCU/RCU list, click the RCU from which you want to delete the path.
4. Right-click, and click Edit SSID(s)&Path(s).
5. Right-click, and click Delete Path. The list changes to the Path Settings Parameter list. Only selected
RCUs are listed.
NOTE: After being set, options can be modified and canceled (see ”Modifying parameters and
deleting settings” on page 75).
6. Click Apply on the Continuous Access XP main pane to apply the deletion to the disk array.
Adding and deleting SSIDs for RCUs (Add SSID/Delete SSID)
Before adding an SSID, ensure that the remote copy connection is properly installed. You can add three
SSIDs to each RCU. Before deleting an SSID, ensure that the remaining SSIDs are valid, or the connection
between the MCU and RCU may be lost.
Use the Add SSID and Delete SSID commands to add and delete SSIDs for an existing RCU. When the Add
SSID command is selected, the Add SSID pane appears.
Figure 41 Add SSID pane
The Add SSID pane displays three SSID fields. You can enter up to three SSIDs at one time with the Add
SSID pane. You can add up to four SSIDs (maximum number of SSIDs).
The Cancel button cancels settings you made. The Set button applies settings you made, and changes the
list.
1. From the CU Number/Port tree on the RCU Operation pane, ensure that the correct CU image is
selected.
2. From the MCU/RCU list, click the RCU.