HP StorageWorks Continuous Access XP Journal user guide (T1778-96001, June 2006)
Continuous Access XP Journal user guide 37
• Primary data volume records updated by host-requested write I/Os after the pair was suspended
Table 8 describes Continuous Access XP Journal suspension conditions and indicates which CU detects
the condition and which pairs are suspended. See ”Displaying the History Operation pane” on page 141
for troubleshooting information for Continuous Access XP Journal suspension conditions.
Table 8 Continuous Access XP Journal suspension conditions
Suspension condition Detected by Continuous Access XP Journal pairs to be
suspended
The secondary array could not copy the journal
data successfully due to a hardware failure or
logic error.
RCU All Continuous Access XP Journal secondary
data volumes in the journal groups, or the
affected secondary data volume
The secondary array detected a logical error
while selecting the journal data to be restored.
RCU All Continuous Access XP Journal secondary
data volumes in the journal group, or only the
affected secondary volume
The secondary array could not restore the
journal data due to a hardware failure, track
condition, or logical error.
RCU All Continuous Access XP Journal secondary
data volumes in the journal groups, or the
affected secondary data volume