HP StorageWorks Continuous Access XP Journal user guide (December 2005)
Continuous Access XP Journal user guide 81
• Remote disk array’s serial number.
• Remote disk array’s controller ID.
NOTE: The controller ID for an XP10000/XP12000 disk array is 4.
• Path group ID. The path group ID is within the range of 1-FF (hexadecimal). Up to 64 path group
IDs can be registered per disk array.
NOTE: In the current version, the path group IDs always take the default values and cannot be
changed.
8. In the Add DKC pane, select a primary and remote disk array port to configure a logical path.
9. Click Option.
10.In the DKC Option pane, configure logical path and disk array options. For more information about the
options, see ”Changing options for logical paths and disk arrays” on page 82.
11.Click Set to close the DKC Option pane.
12.In the Preset list, check the settings you made.
• To modify a setting, select and right-click the setting from the Preset list, and select Modify. A pane
appears where you can modify the setting.
• To cancel a setting, select and right-click the setting in the Preset list, and select Cancel.
13.Click Apply to apply the settings.
NOTE: If an error occurs, the right-most column of the Preset list displays the error code. To view
detailed information about the error, right-click the error code, and select Error Detail. An error
message appears providing detailed information about the error.
Figure 39 Add DKC pane
The Add DKC pane displays the following:
• DKC S/N: Enter the remote disk array’s five-digit serial number.
• Controller ID: Enter the remote disk array’s controller ID (that is, disk array family ID).