HP StorageWorks Continuous Access XP Journal user guide (December 2005)

Continuous Access XP Journal user guide 147
DC 0X Serious Volume being used by the primary
data volume is suspended.
Path recovery is impossible.
Primary disk array SIM Log
DC 1X Serious Volume being used by the primary
data volume is suspended.
Failure detected in the primary disk
array.
Primary disk array SIM Log
DC 2X Serious Volume being used by the primary
data volume is suspended.
Failure detected in the secondary
disk array.
Primary disk array SIM Log
DC 4X Serious Volume being used by the primary
data volume is suspended.
Data volume pair is suspended at
the secondary disk array.
Primary disk array SIM Log
DC 5X Serious Volume being used by the primary
data volume is suspended.
Data volume pair is deleted at the
secondary disk array.
Primary disk array SIM Log
DC 6X Serious Volume being used by the
secondary data volume is
suspended.
Path recovery is impossible.
Primary disk array SIM Log
DC 7X Serious Volume being used by the
secondary data volume is
suspended.
Failure detected in the secondary
disk array.
Secondary disk array SIM Log
Table 32 Typical SIM showing reference code and SIM type (continued)
Reference code Severity Description SIM generated by SVP log file
Byte 22 Byte 23