HP StorageWorks Business Copy XP user guide for the XP128/XP1024 (December 2005)
Business Copy XP user guide for the XP128/XP1024 59
0801 The BC feature could not be used. Ensure that the disk array has the correct
microcode level for BC, the disk array has BC
installed and enabled, and the Command View XP
management station or XP Remote Web Console
has BC installed and enabled.
080B The request could not be accepted. Retry about one minute later.
0810 The specified command cannot be accepted in this
status. (The command was rejected.)
Check the pair status, and ensure that the pair
status is correct for the command.
0811 The specified command is treated as an NOP. The specified command is treated as an NOP.
(NOP means the command can end without errors,
but executes nothing.)
0812 The new pair could not be created because a path
group is set.
Disconnect from host, or cancel Continuous Access
XP path.
On the Continuous Access XP main screen, confirm
the specified S-VOL is simplex, specify the
Delete
Pair by Force
option, and retry the operation.
0813 The Pairsplit command was issued to a pair in the
PSUS status.
The Pairsplit command cannot be issued because
the pair is already in PSUS status.
0814 The Paircreate command was issued to the pair in
the PAIR status.
The Paircreate command cannot be issued because
the pair is already in PAIR status.
0817 A Reserve volume cannot be set because a path
group is set.
Disconnect volume to be reserved from host, or
delete Continuous Access XP path.
0818 The Pairresync or Pairsplit-E command cannot be
issued because a path group is set.
Unmount the S-VOL (offline from the host), or delete
Continuous Access XP path.
081F Command Reject. P-VOL is used from HOST or by
CA.
Disconnect from host, or cancel Continuous Access
XP path.
0830 A pair cannot be created because the track format
is different.
Ensure that the emulation type of the P-VOL and
S-VOL is the same.
0831 A pair cannot be created because a number of
slots is different.
Ensure that the capacity of the P-VOL and S-VOL is
the same.
0834 The emulation type of the specified P-VOL is not
supported by BC.
Ensure that BC supports the emulation type of the
P-VOL.
0835 The emulation type of the specified S-VOL is not
supported by BC.
Ensure that BC supports the emulation type of the
S-VOL.
0836 The pair cannot be created. The emulation type of the P-VOL and S-VOL is not
the same.
0840 Logical contradiction. Call HP technical support for assistance.
0841 Logical contradiction. Call HP technical support for assistance.
0842 Logical contradiction. Call HP technical support for assistance.
0848 Logical contradiction. Call HP technical support for assistance.
0849 Logical contradiction. Call HP technical support for assistance.
084A Logical contradiction. Call HP technical support for assistance.
084B Logical contradiction. Call HP technical support for assistance.
0852 Command Reject. P-VOL and S-VOL are used from
HOST or by CA.
Disconnect from the host, or cancel Continuous
Access XP path.
Error
Code