HP StorageWorks Auto LUN XP user guide for the XP10000/XP12000 (December 2005)

Auto LUN XP user guide for the XP10000/XP12000 39
The status transition chart of a pair when the volume migration is performed by using RAID Manager is
shown in Figure 13. You can view the status shown in this chart by typing pairdisplay in RAID
Manager.
Figure 13 Pair status transitions during Auto LUN XP migrations using RAID Manager
When you perform Auto LUN XP migrations using RAID Manager, the following restrictions apply:
An Auto LUN XP reserved volume cannot be used.
A migration plan being executed by Auto LUN XP cannot be canceled from RAID Manager.
A migration plan created by Auto LUN XP cannot be displayed using RAID Manager.
Before checking RAID Manager settings in a Command View XP or XP Remote Web Console pane,
click All Refresh.
Migration cannot be performed when either of the specified volumes is a LUSE volume.
When you try Auto LUN XP migrations or migration cancellations using RAID Manager, EX_CMDRJE
might appear and the command might be refused, depending on the condition in the disk controller.
Table 10 shows error codes, causes, and solutions for this case.
Table 10 Errors during Auto LUN XP migrations or migration cancellations using RAID Manager
Error code Cause Solution
2051 Migration target volume is being used with LUN
Security XP Extension.
Release the volume from LUN Security XP
Extension, and perform the volume migration.
2055 Migration target volume is being used with
Continuous Access XP Journal.
Release the volume from Continuous Access XP
Journal, and perform the volume migration.
2056 Migration source volume is being used with
Continuous Access XP Journal.
Release the volume from Continuous Access XP
Journal, and perform the volume migration.
2057 VMA setting is different between the migration
target and source volumes.
Volume migration cannot be executed. Check the
configuration definition file.
2058 Migration target and source volumes belong to
the same parity group.
Volume migration cannot be executed. Check the
configuration definition file.
2301 Auto LUN XP is not installed on the
XP10000/XP12000.
Install Auto LUN XP, and perform the volume
migration.
2306 LBA size does not match between the migration
target and source volumes.
Volume migration cannot be executed. Check the
configuration definition file.
2309 Maximum number of pairs that can be set in the
disk array is exceeded.
Reduce the number of pairs set in the disk array,
and perform the volume migration.
2311 Auto LUN XP already reserved the migration
target volume.