HP StorageWorks Audit Log reference guide (5697-5923, June 2006)
Audit Log Reference Guide 153
Table 104 Detailed Information for Set All Prio WWN Operation
Set Ctrl Kind Operation
[PFC]
Performance Control function
Set Ctrl Kind
Set Ctrl Kind operation
Kind=WWN
WWN is selected as the parameter. The operation uses the following parameters, as shown in
Table 105.
Table 105 Parameters for Set Ctrl Kind Operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Item Description
AllPriority The setting status of the All Thresholds value in the WWN tab.
Enable: All Thresholds value is set
Disable: All Thresholds value is cancelled
Threshold The All Thresholds value set.
This value is output only when the All Thresholds value is set.
Mode The rate type of the All Thresholds value.
IOPS: I/O rate, KB/s: Transfer rate
This value is output only when the All Thresholds value is set.
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,[PFC],Set Ctrl
Kind,Kind=WWN,,Normal end,Seq.=xxxxx
Parameter Description
Port Port Control is applied without the All Thresholds value being set.
All Port Port Control is applied with the All Thresholds value being set.
WWN WWN Control is applied. This value is output whether the All Thresholds value is set or