HP Hitachi TrueCopy for Mainframe User Guide (T5211-96014, November 2011)

Table 67 CQUERY Output for ESCON Interface and Fibre Channel Interface
Fibre Channel InterfaceParameters
Mode 484 ONMode 484 OFF
SAID of MCUBit 0-3:RCU controller ID
aa
(x'00' and the port number)x2-xF:Number
stands for the RCU
controller ID.
Bit 4-7:FREEZE option
x0:keep the status
x1:Enabled
x2:Disabled
MCU port number (0x00-0xff)
bb
SAID of RCURCU port number (0x00-0xff)
cc
(x'00' and the port number)
CU number (0x00-0xfe)
dd
“CQUERY Output Example: R-VOL/FORMAT/VOLUME” (page 205) shows the output of the CQUERY
command with the VOLUME parameter issued to a TrueCopy for Mainframe Asynchronous R-VOL.
The LIC LEVEL value in the following figure is example only, not valid number.
The WWNN value in the following figure will be valid if mode 484 is ON. If mode 484 is
OFF, the WWNN value is example only, not valid number.
If mode 484 is ON, the status of path as using the Fibre Channel interface will be displayed.
If mode 484 is OFF, ESCON will be indicated for the path status.
If the former type storage system or the storage system of XP12000/XP10000 Disk Array
microcode version 50-05-XX-XX or earlier is connected, mode 484 must be OFF.
204 Using PPRC Commands for TrueCopy for Mainframe