HP Hitachi TrueCopy for Mainframe User Guide (T5211-96014, November 2011)
Table 67 CQUERY Output for ESCON Interface and Fibre Channel Interface
Fibre Channel InterfaceParameters
Mode 484 ONMode 484 OFF
SAID of MCUBit 0-3:RCU controller ID
aa
(x'00' and the port number)x2-xF:Number
stands for the RCU
controller ID.
Bit 4-7:FREEZE option
x0:keep the status
x1:Enabled
x2:Disabled
MCU port number (0x00-0xff)
bb
SAID of RCURCU port number (0x00-0xff)
cc
(x'00' and the port number)
CU number (0x00-0xfe)
dd
“CQUERY Output Example: R-VOL/FORMAT/VOLUME” (page 205) shows the output of the CQUERY
command with the VOLUME parameter issued to a TrueCopy for Mainframe Asynchronous R-VOL.
• The LIC LEVEL value in the following figure is example only, not valid number.
• The WWNN value in the following figure will be valid if mode 484 is ON. If mode 484 is
OFF, the WWNN value is example only, not valid number.
• If mode 484 is ON, the status of path as using the Fibre Channel interface will be displayed.
If mode 484 is OFF, ESCON will be indicated for the path status.
• If the former type storage system or the storage system of XP12000/XP10000 Disk Array
microcode version 50-05-XX-XX or earlier is connected, mode 484 must be OFF.
204 Using PPRC Commands for TrueCopy for Mainframe