Hitachi TrueCopy (TM) for Mainframe User Guide: HP XP24000 Disk Array, HP XP20000 Disk Array (T5211-96014, May 2011)
Table 88 TrueCopy for Mainframe Scripting Error Codes (continued)
Error DescriptionError MessageInternal CodeMessage ID
$CTG is not described when
asynchronous copy pair
creation.
$CTG not found.53012996
The specified device is not
mounted.
Non device error.4001-
The specified command
cannot be performed under
this pair status.
Pair status error.4002-
The specified command
cannot be performed with
this volume type.
Volume type error.4003-
The description is not found
in the device list of macro.
Device list empty.4004-
An error occurred during the
acquisition of the volume
mounting status.
API error(GetEquipInfoEx).5001-
An error occurred during the
getting pair status operation.
API error(GetPairStatus256).
ErrorCode=6005 xxxx
5002-
An error occurred during the
getting pair status operation.
API error(GetPairStatus).
ErrorCode=6005 xxxx
5003-
An error occurred during the
create pair operation.
API error(SetCreatePair).
ErrorCode=6005 xxxx
5004-
An error occurred during the
suspending pair operation.
API error (SuspendPair).
ErrorCode=6005 xxxx
5005-
An error occurred during the
changing pair options
operation.
API error
(ChangePairOption).
ErrorCode=6005 xxxx
5006-
An error occurred during the
release pair operation.
API error (DeletePair).
ErrorCode=6005 xxxx
5007-
An error occurred at the
copy start instruction.
API error (StartCreatePair).
ErrorCode=6005 xxxx
5008-
An error occurred at retrying
the getting pair status
operation.
API retry (GetPairStatus256).5020-
The number of pairs that is
specified in the device list
exceeds the maximum value.
Too many pairs
(SetList/AddList).
4006-
The operation is interrupted
by a user.
Abort by operator.6666-
The operation is interrupted
according to the modify
mode timeout.
Abort by unlock.6667-
254 TrueCopy for Mainframe Scripting