Hitachi TrueCopy for z/OS user guide (December 2005)
174 TrueCopy for the XP128/XP1024/XP10000/XP12000
D4 3x Serious TC390 for this volume was suspended
because DFW to the R-VOL was blocked.
Yes
2
Repeat
MCU SIM Log
D4 4x Serious TC390 for this volume was suspended due
to an internal error condition detected by
the RCU.
Yes
2
Repeat
MCU SIM Log
D4 5x Serious TC390 for this volume was suspended
because the operator deleted the volume
pair from the RCU.
Yes
2
Repeat
MCU SIM Log
D4 Cx Service The MCU detected a service-level SIM at the
RCU.
Yes
1
Once
RCU SSB Log
D4 Dx Moderate The MCU detected a moderate-level SIM at
the RCU.
Yes
1
Repeat
RCU SIM Log
D4 Ex Serious The MCU detected an acute- or serious-level
SIM at the RCU.
Yes
1
Repeat
RCU SIM Log
D4 Fx Serious The status of the M-VOL is not consistent with
the status of the R-VOL.
Yes
2
Repeat
MCU SIM Log
D5 0x Service TC390 started the initial copy for this
volume, or was out of sync for this volume.
Yes
1
Once
MCU SSB Log
D5 1x Service TC390 completed the initial copy for this
volume.
Yes
1
Once
MCU SSB Log
D5 2x Service The volume pair accepted Delete Pair
operation.
Yes
1
Once
MCU SSB Log
D5 3x Service The volume pair accepted Suspend Pair
operation.
Yes
1
Once
MCU SSB Log
D5 4x Service Delete Pair operation for this volume pair
has completed.
Yes
1
Once
MCU SSB Log
D5 5x Service Suspend Pair operation for this volume pair
has completed
Yes
1
Once
MCU SSB Log
D6 sx Service The R-VOL status has changed as requested
by the MCU. The third digit of the reference
code “s” indicates change of states as
follows:
0: from simplex to pending
1: from simplex to duplex
2: from pending to duplex
3: from pending to suspended
4: from duplex to suspended
5: from duplex to simplex
6: from pending to simplex
7: from suspended to simplex
8: from suspended to pending
Yes
1
Once
RCU SSB Log
Table 43 TrueCopy device SIMs (continued)
Ref. Code Severity Description Reported
to Host
Generated by Log File
22 23