Hitachi TrueCopy for IBM z/OS User and Reference Guide (T5211-96001, June 2007)
Using PPRC Commands for TrueCopy for z/OS A-25
Hitachi Universal Storage Platform V TrueCopy for IBM z/OS User’s Guide
A 00 S 0 G 0
0
30982
Indicates the serial number of the MCU.
Indicates the mode of the volume pair:
1-3
= master pair, (1-3) indicates number of dummy pairs.
D
= dummy pair.
0
= the volume pair is not a master pair or dummy pair.
Indicates the Error Level of this volume pair:
G
for Group,
V
for Volume.
N
= no delay time.
0
= graduated delay.
Indicates the Timer Type of the consistency group:
S
for System,
L
for Local, and
N
for None.
Indicates the consistency group number (00-7F).
Indicates the master volume number for dummy pair mode.
Indicates that this volume pair is TCz Asynchronous, always
A.