Hitachi TrueCopy for IBM z/OS User and Reference Guide (T5211-96001, June 2007)

A-24 Using PPRC Commands for TrueCopy for z/OS
Hitachi Universal Storage Platform V TrueCopy for IBM z/OS User’s Guide
The PATHS, SAID, DEST, STATUS, and DESCRIPTION fields indicate the path
status for this pair. If you issue the CQUERY command to the pair with the
PATH parameter, all paths that can be used for this pair are displayed.
The TRUCKS OUT OF SYNC field indicates the number of trucks out of sync.
The TRUCKS ON VOLUME field indicates the total number of trucks that the
paired volumes have. The PERCENT OF COPY COMPLETE indicates the
percentage of cylinders that have already been copied for pair
resynchronization.
The MCU serial number field is used to display the following TCzA information:
For 2105 and 2107 controller emulation:
A 7F S 0
V
0
0
0
0
Indicates the mode of the volume pair:
1-3
= master pair, (1-3) indicates the number of dummy pairs.
D
= dummy pair.
0
= the volume pair is not a master pair or dummy pair.
Indicates the Error Level of this volume pair:
G
for Group,
V
for Volume.
N
= no delay time.
0
= graduated delay.
Indicates the Timer Type of the consistency group:
S
for System,
L
for Local, and
N
for None.
Indicates the consistency group number (00-7F).
Indicates the master volume number for dummy pair mode.
Indicates that this volume pair is TCz Asynchronous, always
A.
00
For 3990-3, -6, and -6E controller emulations: