Hitachi ShadowImage for z/OS user guide (HIT9503-96007, October 2007)

ShadowImage for z/OS user guide 121
CAUTION: If an SIz S-VOL is in pending status and you execute an ICKDSF command for FlashCop
Mirror Version 2 , the ICKDSF job will end abnormally with CC=12 error. Table 7.22 describes how to
avoid that abnormal ending.
CAUTION: You cannot create the FlashCopy® Mirror Version 2 pair since the data consistency of the
FlashCopy® Mirror Version 2 T-VOL will not be insured.
CAUTION: If you create a FlashCopy® Mirror Version 2 pair with the FREEZE option when FlashCopy®
Mirror Version 2 S-VOL and TCz Synchronous R-VOL are shared, the results of FlashCopy® Mirror Version
2 operations and TCz Synchronous operations will be as follows:
When you use FlashCopy® Mirror Version 2 S-VOL as the TCz R-VOL, configure the system as follows.
Connect different hosts to main subsystem and remote subsystem, or connect the host of main subsystem
to both main and remote subsystem.
Use the fibre channel interface to connect main subsystem with remote subsystem.
TCzA M-Vol
OK OK
3
OK
R-Vol No
1
No
1
OK
1
You cannot create the FlashCopy® Mirror Version 2 pair since the
data consistency of the FlashCopy® Mirror Version 2 T-VOL will not
be insured.
2
If you create a FlashCopy® Mirror Version 2 pair with the FREEZE
option when FlashCopy® Mirror Version 2 S-VOL and TCz
Synchronous R-VOL are shared, the results of FlashCopy® Mirror
Version 2 operations and TCz Synchronous operations will be as
follows:
Results of FlashCopy® Mirror Version 2 operations
When the status of TCz Synchronous pair is Suspend, the
command will end normally and you can create a FlashCopy®
Mirror Version 2 pair. However, when the status of TCz
Synchronous pair is either Duplex of Pending duplex, the
command will be rejected and you cannot create a FlashCop
Mirror Version 2 pair.
Results of TCz Synchronous operations
If a FlashCopy® Mirror Version 2 pair is created with the FREEZE
option, and when a TCz Synchronous R-VOL is in extended long
busy (ELB) status, the command to create or resume a pair will be
rejected. However, the command to suspend or delete a pair will
be executed normally.
3
If a TrueCopy for z/OS M-VOL is in pending status and you execute
an ICKDSF command for FlashCopy® Mirror Version 2 , the ICKDSF
job will end abnormally with CC=12 error. Table 7.22 describes how
to avoid that abnormal ending.
Table 53 Volume Share of FlashCopy® Mirror Version 2 S-VOL and TCz
Shared TCz Pair Volume Status of TCz Pair
Duplex Pending
Duplex
Suspend