Removal and replacement procedures 43
If the screws lack Nylok coating or are used, add Loctite 242 Threadlocker 3~5 threads from the tip.
5. Install M2.5x6 mm wafer head screw through the plate tab and process control board hole alignment
to the baseplate, and then torque screw to 4.0~4.5 in-lbf.
If the screw does not have Nylok coating, or are used, add Loctite 242 Threadlocker 3~5 threads from