HP ProLiant Storage Server with Windows Storage Server 2003 SP1 - Release Notes (378129-401, October 2006)
Additional app lications and u tilities
Workaround To convert the storage server into Japanese:
1. Connect a keyboard, monitor, and mouse.
2. Login to the local c onsole using the administrator account. The default
password is hpinvent.
3. Select Run from the Start menu.
4. Enter the following:
c:\hpnas\Conv.vbs
NOTE:
If you are run
ning an earlier version of the ProLiant ML350 G4p
Storage Server, and the above command did not work , then enter:
c:\hpnas\Components\Localization\Convjp.vbs.
5. Select Yes to convert the system to Japanese and restart the server.
Issue:
Blue screen (BSOD) triggered by a ccessing Storage Manager 2.0 components
Description
An issue has been discovered where the storage server can crash and reboot
when Storage Manager 2.0 components are accessed. Components include
directory quotas, storage reports, and file screening. This issue only exists
when both Op enView Storage Mirroring 4.3.3 a nd Symantec AntiVirus 9.0 are
installed and running on the storage server and the system is running under at
least a moderate load.
NOTE:
Load on the server includes client activity, reading, and writing to the server
storage. Moderate load is defined differently depending on which storage
server platform is used.
Workaround
To avoid this issue, stop the auto-protect feature of the Symantec AntiVirus product
before running the Storage Manager components. Restart auto-protect when
finished.
Issue:
Write cache disabled on ML110 G1, ML110 G2,DL100,DL100G2,ML350G4p,andML310G3
Description
The Adaptec 2410SA, 2420SA, and 2610SA controllers contain cache memory
that may be used for read ahead or write back. Enabling the write back cache
improves performance by allowing the operating system to assume the write made
it to disk when in fact the write only made it to the onboard memory. While this
does improve performance substantially, data loss can occur on writes that make
it to memory but not to disk in the event of a power failure to the unit.
Workaround HP recommends that an uninterruptible power supply (UPS) be used with the
unit for cache enablement to ensure that data loss does not occur. Cache
memory may be adjusted via the Adaptec Storage Manager utility (refer to the
administration guide) or via the ROM based setup. By default, the Adaptec
Storage Manager sets the write cache to enabled on newly created logical disks
via the tool. The setting should be reviewed and set appropriately if a new lo gical
device is created by the user.
Issue:
Internet Explorer defaults to the Windows Update page from t he Microsoft web site
Description
In some instances, Internet Explorer defaults to the Windows Update page instead
of the local host when using Internet Explorer from the local desktop.
Workaround Go to the address bar and enter https://Localhost:3202.
Storage Server with Windows Storage Server 2003 SP1 release notes
33