HP ProLiant SL170z G6 Server Maintenance and Service Guide
Contents 77
Table 10 POST Error Messages
Error Code
Error Message
Description/Corrective Action
607h System Fan 4 Missing
If system fan4 is not installed or
failed, system will announce this
message and system will shutdown
in minutes.
608h
Fan Solution Not Sufficient!
Critical Failure Detected - System
Shutting Down in xx seconds!
If one or more fans are missing, this
message will appear with 'system
fan x missing' together.
609h
Temperature Violation Detected!
Waiting 5 minutes for system to
cool.
Press ESC Key to resume booting
without waiting for the system to
cool.
Warning: Pressing ESC is NOT
recommended as system may
shutdown unexpectedly.
Recheck Temperature in xxx
seconds!
If system detects one or more
temperature sensors overheating,
this message will appear.
612h
Power Supply Failure or Power
Supply Unplugged
When two power supplys are
installed, if one of the power cables
is not connected or one of the
power is failed, this will appear.
611h System Event Log full
If system cannot store any more
event log, this will appear at post.
615h
System Fan 1 missing!
The cooling solution is not
redundant due to a detected fan
failure.
If only system fan1 is not installed or
failed, system will announce this
message and press F1 continue to
boot
616h
System Fan 2 missing!
The cooling solution is not
redundant due to a detected fan
failure.
If only system fan2 is not installed or
failed, system will announce this
message and press F1 continue to
boot
617h
System Fan 3 missing!
The cooling solution is not
redundant due to a detected fan
failure.
If only system fan3 is not installed or
failed, system will announce this
message and press F1 continue to
boot
618h
System Fan 4 missing!
The cooling solution is not
redundant due to a detected fan
failure.
If only system fan4 is not installed or
failed, system will announce this
message and press F1 continue to
boot