HP ProLiant SL170z G6 Server Maintenance and Service Guide

Contents 60
Item
Designator
Description
14 XU1 Processor 1 socket
15 J36 Power connector
16 J42 RPS connector
17 J1~J8 DDR3 DIMM slots
18 XU2 Processor 2 socket
19 J45 Protected RTC jumper
20 J24 Riser connector
21 J57 TPM connector
CAUTION: The TPM is not a customer-removable part.
Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security
rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider
the system compromised and take appropriate measures to ensure the integrity of the system data.
If you suspect a TPM board failure, leave the TPM installed and remove the system board. Contact
an HP authorized service provider for a replacement system board and TPM board.
Jumpers Password and Chassis ID
Password (J50) and chassis ID (J45) jumpers
Table 4 describes the jumper settings.
Table 4
System configuration switch settings
Jumper Status
J50 1-2, password reset
J45 1-2, default setting, 2-3 Clear CMOS