HP ProLiant SL165z G7 Server Installation Sheet

Toinstallaharddriveintheservertray:
1. Unlock the HDD carrier latches.
2. Rotate the HDD carrier handle up.
3. AlignthevepinsontheHDDcarriertotheirholesonthetwosidesofthe
server tray, and insert the HDD into the server tray
4. PushtheHDDalongthedirectionofthearrowtolockthevepins.
5. Rotate the HDD carrier handle down.
6. Lock the HDD carrier latches.
Figure 6 Installing the Hard Drive
Installing a memory module
CAUTION: DIMMs can be damaged by improper handling. Always
use an anti-static wrist strap and grounding mat, and discharge static
electricity before touching DIMMs.
NOTE: Referto“Systemboardcomponents”inthisdocumentfortheDIMMlocations.
Toinstallthememorymodule:
1. Align the notch on the bottom edge of the memory module with the keyed
surface of the DIMM slot and then fully press the memory module into the slot
until the holding clips snap back in place.
Figure 7 Installing the Memory Module
CAUTION: DIMM slots are structured to ensure proper installation. If you
insertaDIMMbutitdoesnotteasilyintotheslot,youmayhaveinserted
it incorrectly. Reverse the orientation of the DIMM and insert it again.
Installing a processor
Toinstalltheprocessor:
1. For AMD processor with installation tool, use the processor installation tool to
insert the processor into the socket, using the keys on the processor.
2. Remove the processor installation tool.
3. Engage the retention plate and the load lever.
Figure 8 Installing the Processor
For processor removal, reverse the above installation procedures.
CAUTION: With the load lever and the retention plate disengaged, hold
the processor by its edges and align it over the empty processor socket.
Make sure that you properly align the processor with the orientation notch
on the socket.
CAUTION: To prevent overheating or a possible system crash, use only a
heatsinkmodelspeciedfortheHPProLiantSL165zG7Server.
CAUTION: Align pin 1 on the processor with pin 1 on the processor
socket, or pin damage will occur.
CAUTION: HP recommends using Shin-Etsu X-23-7783D thermal grease
compound for your ProLiant server. Apply the grease to the top of
theprocessorineithera5“Dot”or“S”shapedpattern.Ensureeven
distribution.
Toinstalltheheatsink:
1. Properly align the heat sink spring-loaded screws to the system board mounting
holes.
2. Tighten the spring-loaded screws clockwise to secure the heat sink connection to
the system board.
Figure 9 Installing the Heat Sink Assembly
CAUTION: Be sure that the heat sink sits squarely on the processor, or
overheating and damage to the processor may occur.
NOTE: When installing two heat sinks, it is recommended to put the heat sinks with
the15-nsidefacingtheDIMMs.
CAUTION: Do not over-tighten the spring-loaded screws to prevent them
frombreakingoff.Amaximumtorqueof7inch-lbissetforeachscrew.
Rotate the heat sink a few degrees to the left and right to break the
bonding of the thermal grease before removing the heat sink from the
processor.
IMPORTANT: If the heat sink has been removed for any reason, it is critical
that you apply more thermal interface material to the integrated heat
spreader on the processor to ensure proper thermal bonding between
the processor and the heat sink. Clean the contact surface of both the
processor and heat sink with an alcohol pad, then re-apply an HP-
approved thermal interface material before reinstalling the processor. Use
apatternofvedotswhenapplyingthethermalinterfacematerial—one
dot in the center, and one dot at each corner.
CAUTION: For proper cooling, do not operate the server without the top
cover,airbafe,expansionslotcovers,orblanksinstalled.Foradditional
information, see the user guide. If hot-plug components are supported,
minimize the amount of time the top cover is removed.
Installing the system fans
Thegurebelowidentiesthesystemfansbytheirdevicenumberandshowstheir
corresponding cable connections.
Figure 10 Installing the System Fans
Installing the SD card reader
module
ToinstalltheSDcardreadermodule:
1. Remove the SD card reader module knock-out from the front panel of the server.
2. Align the SD card reader module to the front panel, and tighten the screw that
secures the module to the server.
3. Connect the USB cable to the SD card reader module USB connector and link
the other side of the USB cable connector to the system board.
Figure 11 Installing the SD Card Reader Module
NOTE: You must use the slotted driver to remove the knock-out.
Installing the dedicated
management port card
Toinstallthededicatedmanagementportcard:
1. Remove the dedicated management port knock-out from the front panel of the
server.
2. Insert the dedicated management port card into the mgmt card connector on
the system board.
3. Tighten the screw clockwise to secure the dedicated management port card to
the system board.
Figure 12 Installing the Dedicated Management Port Card
Additional documentation
For additional documentation, refer to HP ProLiant DL165/SL165z G7 Easy Set-up
CD. You can also access additional information and documentation from the HP
externalwebsite,eitherbyconnectingdirectlyorthroughtheEasySet-upCD.
Legal notices
© Copyright 2010 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties
forHPproductsandservicesaresetforthintheexpresswarrantystatementsaccompanying
such products and services. Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Processor memory socket
Rank support per memory socket
RDIMM Population order without QR
UDIMM Population order without QR
Population order with QR along with SD/DR
Processor memory bank number
Memory Module Population Order
NOTES: