HP ProLiant SL160z G6 Server Maintenance and Service Guide
Physical and Operating Specifications 77
Table 13 Environmental Specifications
Item
Description
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr
LWad: 6.7 Bels
(operating at room temperature)
LWad: 6.7 Bels
(Idle at room temperature)
Table 14 Hot-Plug Power Supply Specifications
Item Description
Dimensions (H x W x D) 38.48 mm x 86.36 mm x 190.52 mm
Weight (approximate)
1.1 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC /200 VAC to 240 VAC
Line frequency 50Hz – 60Hz
Rated input current
Max: 10A
BTU rating N/A
Power supply output power:
Rated steady state power
Maximum peak power
460W /750W/1200wW
N/A
Temperature range:
Operating
Storage/Shipping
+5° to +50°
–40° to +85°
Relative humidity:
Operating
Non-operating
5% to 95% relative humidity, non-condensing.
5% to 95% relative humidity, non-condensing