HP ProLiant SL160z G6 Server Maintenance and Service Guide

Connectors, Switches, and LEDs 59
Item
Designator
Description
13 J11 MINI SAS CONN
14 J69 USB4
15 J3 Storage card slot
16 J56 LCD Connector
17 B1 BATTERY
18 J82 PS backplane connector
19 J65 BP I2C CONN
20 J42 FRONT PANEL CONN
21 J67,J68,J70,
J62,J71
FAN CONN
22
J64
12V POWER CONN
23 J57,J58 SATA HDD CONN
24 J63 FAN CONN
25 J47,J47,J76:
J46,J45,J75:
J43,J44,J74
MEMORY DIMM CONN
26
J51
SYSTEM POWER CONN
27 U73 Processor 1 Socket
28 J60 12V POWER CONN
29 U34 Processor 2 Socket
CAUTION: The TPM is not a customer-removable part.
Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security
rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider
the system compromised and take appropriate measures to ensure the integrity of the system data.
If you suspect a TPM board failure, leave the TPM installed and remove the system board. Contact
an HP authorized service provider for a replacement system board and TPM board.
Jumpers Password and Chassis ID
Password (J50) and chassis ID (J45) jumpers. Table 4 describes the jumper settings.
Table 4
System configuration switch settings
Jumper
Status
J50
1-2, password Reset
J45 1-2, default setting, 2-3 Clear CMOS