ProLiant ML570 Generation 2 Server Maintenance and Service Guide
Connectors, LEDs, and Switches
Table 4-8: Single-Board Mirrored Memory LEDs
Item Description Indicator Status
Off Memory board is offline.
Green Memory board is online.
Flashing green Memory board is busy.
1 Memory status
Amber Memory error has occurred on this
memory board.
Off Memory board is not configured for
mirrored memory.
Green Single-board mirrored memory is
functioning properly.
3 Mirroring status
Amber Memory error has occurred and system
has failed over to the mirrored bank(s).
Off DIMM is not installed.
Green DIMM is installed.
Amber Memory error has occurred on this
DIMM.
8 DIMM 1-8 status
Flashing amber Configuration error has occurred.
1-4,
7, 8
All LEDs Flashing amber Memory board is in use; relock it
immediately.
4-10 HP ProLiant ML570 Generation 2 Server Maintenance and Service Guide