HP ProLiant ML570 Generation 2 Server Setup and Installation Guide

System LEDs and Switches
C-14 HP ProLiant ML570 Generation 2 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Wendy Wing File Name: l-appc System LEDs and Switches.doc
Codename: Time Bandit Part Number: 223960-002 Last Saved On: 8/22/02 11:22 AM
Table C-11: Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED
Online
LED
Fault
LED
State
On Off Off
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is being accessed and is not configured as part of an
array.
On Flashing Off
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is rebuilding or undergoing capacity expansion.
Flashing Flashing Flashing
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off Off Off OK to replace the drive online if a predictive failure alert is
received and the drive is attached to an array controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, a powered-on controller is not
accessing the drive.
-Or-
The drive is configured as an online spare.
Off Off On OK to replace the drive online.
The drive has failed and has been placed offline.
Off On Off OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
On or
flashing
On Off OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and being accessed.