4. Test the DIMMs and configure the memory mode through RBSU:
a. Power on the server.
b. Press the F9 key to enter RBSU.
c. Select Advanced Options.
d. Change POST Speed Up to disable.
e. Press any key to return to the RBSU main menu.
f. Select System Options.
g. Select Advanced Memory Protection.
h. Select the desired memory mode.
i. Press the ESC key twice to go back to the main RBSU menu.
j. Press the F10 key to exit RBSU. The server reboots and tests all memory in
the system.
k. Once the memory has been tested, re-enable POST Speed Up for faster
system boot, if desired.
IMPORTANT: To reconfigure the memory mode after initial setup, you must reboot the
system and enter RBSU.