HP ProLiant ML500 Series Generation 2 Server Memory Installation Guide

Memory
1-16 HP ProLiant ML500 Series Generation 2 Server Memory Installation Guide
HP CONFIDENTIAL
Writer: Jim Yurick File Name: b-ch1 Memory.doc
Codename: Time Bandit Part Number: 279987-002 Last Saved On: 8/23/02 1:07 PM
Provides notification of the DIMM failure via the memory board LEDs, the
front-panel internal health LED, and Insight Manager 7.
This process occurs without intervention or server interruption, and enables you to
replace the degraded DIMM at your convenience during a regularly scheduled
shutdown.
DIMM Installation Requirements
In addition to the DIMM configuration requirements for advanced ECC memory,
observe the following DIMM configuration requirements when installing DIMMs for
online spare memory:
Memory board slot 1 must be populated.
Bank D on the memory board in slot 1 is always the online spare bank, even if
two memory boards are installed, and must be populated when the server is
configured for online spare memory.
DIMMs installed in the online spare bank must be of equal or greater capacity
than each of those in the remaining banks on both memory boards.
IMPORTANT: If any of the above requirements is not met, the system automatically switches
to advanced ECC memory and displays an error message during POST.