Compaq ProLiant ML530 Setup and Installation Guide

Server Installation 3-21
Compaq Confidential Need to Know Required
Writer: Tricia Acevedo Project: Compaq ProLiant ML530 Setup and Installation Guide Comments:
Part Number: 139006-002 File Name: d-ch3 Installation.doc Last Saved On: 6/15/00 9:02 AM
3. Insert the tip of the fitting tool through the other side of the perforation
and hook the opposite lip of the cage nut.
Figure 3-13. Inserting cage nuts
4. Using the fitting tool as a lever, pry the cage nut into position.
5. Repeat for each cage nut.
Attaching the Mounting Bracket Assembly to
the Rack
The tabs on the front of the mounting bracket help to align it with the front of
the rack frame. Cage nuts are not used for the front attachment of the
mounting bracket.
1. Using the pencil marks from the template, carefully align the rack
mounting bracket assembly with the rear rack frame rail.
2. Using the tabs, insert the rear end of the rack mounting bracket into the
rear rack frame rail.