ProLiant ML530 Generation 2 Server Setup and Installation Guide
Server Specifications
E-2 HP ProLiant ML530 Generation 2 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: n-appe Server Specifications.doc
Codename: Seattle Slew Part Number: 225579-002 Last Saved On: 1/8/03 3:25 PM
Table E-1: Server Specifications
Feature Units
Dimensions
Height (without casters) 51.5 cm (20.3 in)
Depth (without bezel) 69.7 cm (27.5 in)
Width 32.6 cm (12.9 in)
Weight 45.4 kg (100 lb) to 66.2 kg (146 lb)
Input requirements
Rated input voltage 100–127 VAC
200–240 VAC
Rated input frequency 47–63 Hz
Rated input current 10A for 100–127 VAC
4.8A for 200–240 VAC
Rated input power 1000W for 100–127 VAC
960W for 200–240 VAC
BTUs per hour 3415 BTUs/hr 100–127 VAC
3015 BTUs/hr 200–240 VAC
Power supply output
Rated steady-state power Rated steady-state power: 600 W
Maximum peak power Maximum peak power: 600 W
Temperature range
Operating
10° to 35°C (50° to 95°F)
Shipping
-30° to 60°C (-20° to 140°F)
Relative humidity (non-condensing)
Operating 20% to 80%
Non-operating 5% to 90%
Wet bulb temperature
38.7°C (101.7°F)
Heat dissipation 2400 BTUs/hr maximum