ProLiant ML530 Generation 2 Server Setup and Installation Guide

System LEDs and Switches
HP ProLiant ML530 Generation 2 Server Setup and Installation Guide C-19
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: l-appc System LEDs and Switches.doc
Codename: Seattle Slew Part Number: 225579-002 Last Saved On: 1/8/03 3:23 PM
Table C-12: System LEDs and Internal Health LED Status Combinations continued
System LED and Color Internal Health
LED Color
State
DIMM failure, all slots in one
bank (flashing amber)
Red Configuration error: The indicated DIMMs
are not properly populated or are an
unsupported type.
DIMM failure, all slots (amber) Red No valid or usable memory is installed in
the system.
Memory board interlock (amber) Red No memory board is installed.
Thermal warning (amber) Red System has exceeded OS cautionary level
or critical hardware level.
Red A required fan has failed or is missing. Fan (amber)
Amber A redundant fan has failed.
Red A required power supply has failed. Power supply (off)
Amber A redundant power supply has failed.