Table C-11: Hot-Plug SCSI Hard Drive LED Combinations continued
Activity
LED
Online
LED
Fault
LED
State
Off Off On OK to replace the drive online.
The drive has failed and has been placed offline.
Off On Off OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
On or
flashing
On Off OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.