HP ProLiant ML370 Generation 3 Setup and Installation Guide
Installing Hardware Options
HP ProLiant ML370 Generation 3 Server Setup and Installation Guide 3-67
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: d-ch03 Installing Hardware Options.doc
Codename: Dizzy Devil Part Number: 281992-002 Last Saved On: 12/3/02 12:45 PM
Redundant Hot-Plug Power Supply
The server supports a second hot-plug power supply to provide redundant power to
the system in the event of a failure in the primary power supply. You can install or
replace a second hot-plug power supply without powering down the server.
CAUTION: If only one power supply is installed, do not remove the power supply
unless the server has been powered down. Failing to power down before removing a
power supply in a non-redundant configuration could cause data loss.
To install a second hot-plug power supply:
1. Locate the secondary hot-plug power supply bay.
Figure 3-57: Hot-plug power supply bays
Table 3-13: Hot-Plug Power Supply Bays
Item Description
1 Secondary (redundant) hot-plug power supply blank
2 Primary hot-plug power supply