Table 4-14
Server Manager/R Board Test Error Codes
continued
Error Code Description Recommended Action
7061-xx Voice/DTMF Internal Loopback
test failed.
7062-xx Voice/DTMF Internal Loopback
test failed.
Replace the Server Manager/R board Voice ROM.
7078-xx Host ADC Measurements test
failed.
7079-xx Battery test failed.
Replace the Server Manager/R board battery.
8600 - 8699, Pointing Device Interface Test Error
Codes
The 8600 series of diagnostic error codes identifies failures with the pointing
device (mouse, trackball, and so forth) or the system board assembly.
Corrective action may require replacement of the pointing device or the
system board assembly.
Table 4-15
Pointing Device Interface Test Error Codes
Error Code Description Recommended Action
8601-xx Pointing Device Interface test failed. The following steps apply for the 8601-xx error
codes:
1. Replace with a working pointing device
and retest.
2. Replace the system board and retest.