Compaq ProLiant ML350 Server General Troubleshooting Guide

Diagnostic Tools 4-19
Compaq Confidential Need to Know Required
Writer: Susana Weinstein Salazar Project: Compaq Servers Troubleshooting Guide Comments:
Part Number: 161434-001 File Name: e-ch4 Diagnostic Tools.doc Last Saved On: 9/2/99 1:50 PM
6500 - 6599, SCSI Hard Drive Test Error Codes
The 6500 series of diagnostic error codes identifies failures with SCSI hard
drives, SCSI hard drive controller boards, SCSI hard drive cabling, and system
board functions. If the system uses a drive array controller, see the section for
Array Diagnostic Utility (ADU).
Table 4-11
SCSI Fixed Disk Drive Test Error Codes
Error Code Description Recommended Action
6500-xx SCSI Disk ID drive types test failed.
6502-xx SCSI Disk Unconditional Format test
failed.
6505-xx SCSI Disk Read Test Failed.
6506-xx SCSI Disk SA/Media test failed.
6509-xx SCSI Disk Erase tape test failed.
6523-xx SCSI Disk Random Read test failed.
6528-xx Media load/unload test failed.
1. Run the System Configuration Utility and
verify the drive type.
2. Replace the SCSI disk drive signal and
power cables and retest.
3. Replace the SCSI controller and retest.
4. Replace the SCSI disk drive and retest.
5. Replace the system board and retest.