Compaq ProLiant ML350 Server General Troubleshooting Guide
Diagnostic Tools 4-17
Compaq Confidential – Need to Know Required
Writer: Susana Weinstein Salazar Project: Compaq Servers Troubleshooting Guide Comments:
Part Number: 161434-001 File Name: e-ch4 Diagnostic Tools.doc Last Saved On: 9/2/99 1:50 PM
1200 - 1299, Modem Communications
Test Error Codes
The 1200 series of diagnostic error codes identifies failures with the modem.
Corrective action may require replacement of the modem.
Table 4-9
Modem Communications Test Error Codes
Error Code Description Recommended Action
1201-xx Modem internal loopback test failed.
1202-xx Modem time-out test failed.
1203-xx Modem external termination test
failed.
1204-xx Modem auto-originate test failed.
1206-xx Dial multi-frequency tone test failed.
1210-xx Modem direct connect test failed.
The following steps apply to error codes
1201-xx through 1210-xx:
1. Refer to the modem documentation for
correct setup procedures and retest.
2. Check the modem line and retest.
3. Replace the modem and retest.