Compaq ProLiant ML350 Server General Troubleshooting Guide

4-16 Compaq Servers Troubleshooting Guide
Compaq Confidential Need to Know Required
Writer: Susana Weinstein Salazar Project: Compaq Servers Troubleshooting Guide Comments:
Part Number: 161434-001 File Name: e-ch4 Diagnostic Tools.doc Last Saved On: 9/2/99 1:50 PM
1100 - 1199, Serial Test Error Codes
The 1100 series of diagnostic error codes identifies failures with serial/parallel
interface board or system board functions. Corrective action may require
replacement of the serial/parallel interface board or the system board
assembly.
Table 4-8
Serial Test Error Codes
Error Code Description Recommended Action
1101-xx Serial port test failed.
1109-xx Clock register test failed.
The following steps apply to error codes
1101-xx and 1109-xx:
1. Check the switch settings on the
Serial/Parallel Interface board (if
applicable) and retest.
2. Replace the Serial/Parallel Interface
board (if applicable) and retest.
3. Replace the system board and retest.