Compaq ProLiant ML350 Server General Troubleshooting Guide

Diagnostic Tools 4-15
Compaq Confidential Need to Know Required
Writer: Susana Weinstein Salazar Project: Compaq Servers Troubleshooting Guide Comments:
Part Number: 161434-001 File Name: e-ch4 Diagnostic Tools.doc Last Saved On: 9/2/99 1:50 PM
600 - 699, Diskette Drive Test Error Codes
The 600 series of diagnostic error codes identifies failures with diskette,
diskette drive, or system board functions. Corrective action may require
replacement of the diskette, the diskette drive, or the system board assembly.
Table 4-7
Diskette Drive Test Error Codes
Error Code Description Recommended Action
600-xx Diskette ID drive types test failed.
601-xx Diskette format failed.
602-xx Diskette read test failed.
603-xx Diskette write/read/compute test
failed.
604-xx Diskette random seek test failed.
605-xx Diskette ID media failed.
606-xx Diskette speed test failed.
607-xx Diskette wrap test failed.
608-xx Diskette write protect test failed.
609-xx Diskette reset controller test failed.
610-xx Diskette change line test failed.
The following steps apply to error codes
600-xx through 698-xx:
1. Replace the diskette and retest.
2. Check and/or replace the diskette power
and signal cables and retest.
3. Replace the diskette drive and retest.
4. Replace the system board and retest.
699-xx Diskette drive/media ID error. The following steps apply to the 699-xx error
codes:
1. Replace the media and retest.
2. Run the Configuration utility and retest.