Compaq ProLiant ML350 Server General Troubleshooting Guide

Diagnostic Tools 4-9
Compaq Confidential Need to Know Required
Writer: Susana Weinstein Salazar Project: Compaq Servers Troubleshooting Guide Comments:
Part Number: 161434-001 File Name: e-ch4 Diagnostic Tools.doc Last Saved On: 9/2/99 1:50 PM
Table 4-2
Primary Processor Test Error Codes
continued
Error Code Description Recommended Action
122-xx Multiprocessor Dispatch test
failed.
123-xx Interprocessor Communication
test failed.
1. Check the system configuration and retest.
2. Replace the processor and retest.
3. Replace the system board and retest.
199-xx Installed devices test failed. 1. Check the system configuration and retest.
2. Verify cable connections and retest.
3. Check switch and/or jumper settings and
retest.
4. Run the Configuration utility and retest.
5. Replace the processor and retest.
6. Replace the system board and retest.