100 - 199, Primary Processor Test Error Codes
The 100 series of diagnostic error codes identifies failures with processor and
system board functions. Corrective action may require replacing system boards
or processor assemblies.
Table 4-2
Primary Processor Test Error Codes
Error Code Description Recommended Action
101-xx CPU test failed. Replace the processor and retest.
103-xx DMA page registers test failed.
104-xx Interrupt controller master test
failed.
105-xx Port 61 error occurred.
106-xx Keyboard controller self-test
failed.
For error codes 103-xx through 106-xx, replace the
processor and retest.
107-xx CMOS RAM test failed.
108-xx CMOS interrupt test failed.
109-xx CMOS clock load data test
failed.
The following steps apply to error codes 107-xx
through 109-xx.
1. Replace the battery/clock module and retest.
2. Replace the system board and retest.
110-xx Programmable timer load data
test failed.
111-xx Refresh detect test failed.
113-xx Protected mode test failed.
For error codes 110-xx through 113-xx, replace the
system board and retest.
114-xx Speaker test failed. 1. Verify the speaker connection and retest.
2. Replace the speaker and retest.
3. Replace the system board and retest.
116-xx Cache test failed. Replace the system board and retest.