HP ProLiant ML350 Generation 4p Server Maintenance and Service Guide

Removal and replacement procedures 32
Second serial port
To remove the component:
1. Power down the server ("Powering down the server" on page 13).
2. Do one of the following:
Unlock and remove the bezel ("Front bezel (tower model)" on page 15).
Extend the server from the rack ("Extending the server from the rack" on page 13).
3. Remove the access panel ("Access panel" on page 14).
4. Open the retention clip securing the second serial port.
5. Remove the serial port cable from the serial port header on the system board.
6. Remove the second serial port option.
To replace the component, reverse the removal procedure.
Duplex SCSI backplane
To remove the component:
1. Power down the server ("Powering down the server" on page 13).
2. Do one of the following:
Unlock and remove the bezel ("Front bezel (tower model)" on page 15).
Extend the server from the rack ("Extending the server from the rack" on page 13).
3. Remove the access panel ("Access panel" on page 14).